Click photo to enlarge

queensland-sheet-metalAccessories General AccessoriesAvailable

Dektite Roof Penetration Flashings

Red Dektite - No. 4 is a flexible metal-roof penetration flashing for round pipes and flues measuring 75 to 160 mm. Select by actual outside diameter, not nominal pipe size.

Dektite Option
No. 4
Roof Pitch
0° to 40°
Pipe outside diameter
75 to 160 mm(3 to 6 1/4 in)
Material
High-temperature silicone, -50°C to 200°C continuous
Category
Accessories General Accessories
  • Pipe outside diameter: 75 to 160 mm
  • High-temperature silicone, -50°C to 200°C continuous
  • Roof pitch range: 0° to 40°
  • Flexible reinforced base forms to profiled metal roofing
  • Marked cone guides trimming to the measured penetration

SKU CSA-283D90165513

$62.13

Ex GST. Freight calculated at checkout.

Or request a quote for custom lengths / large volumes

Overview

Red Dektite - No. 4 seals round pipes and flues where they pass through profiled metal roofing. The flexible reinforced base forms to corrugated and ribbed roof sheets, while the cone is trimmed at the marked diameter to make close contact around the penetration.

The No. 4 mark is a product size code, not a pipe measurement. This option covers pipe outside diameter from 75 to 160 mm (3 to 6 1/4 in). Measure the outside of the installed pipe, including any insulation or outer casing that passes through the flashing, before choosing a size.

High-temperature silicone is rated for -50°C to 200°C continuous. This option is listed for roof pitches from 0° to 40°. Use the manufacturer installation method, approved sealant and suitable roof fasteners. Installation by a qualified roof plumber is recommended because poor trimming or fixing can cause water entry.

Choose the right Dektite size

The number is a product code, not the pipe diameter. Measure the outside diameter of the pipe, flue or post where it passes through the roof, then select that size from the Size menu.

01

Measure outside diameter

Measure the full outside width at the roofline. Include insulation or casing that must pass through the boot.

02

Match the stated range

Choose the smallest option whose range contains the measurement and whose base can form over the roof ribs.

03

Choose the material

Use standard EPDM for normal roof temperatures, red silicone for hot flues, and square for square posts.

Sizing reference: DEKS Dektite manufacturer chart. Confirm the measured penetration, roof pitch and service temperature before ordering.

Technical Specifications

Dektite sizeNo. 4
Pipe outside diameter75 to 160 mm
Imperial size range3 to 6 1/4 in
MaterialHigh-temperature silicone
Continuous temperature range-50°C to 200°C continuous
Roof pitch range0° to 40°
Selection measurementActual outside diameter, including any casing through the flashing
Unit of measureMetric
CSA SKUCSA-283D90165513

Compliance

Standards & Certifications

DEKS sizing reference

The displayed 75 to 160 mm range comes from the manufacturer chart for this Dektite size. Always check the actual outside diameter before ordering.

DEKS Dektite sizing chart

UV and fire test information

DEKS lists UV testing and AS 1530.8.1 certification for the Dektite range. Check the selected material and project fire requirements before specification.

AS 1530.8.1

Datasheets, Guides & Certificates

Manufacturer documentation for specification and compliance. Links open the original source documents.

Use Cases

  • Plumbing vent pipes
  • Hot and cold flues
  • HVAC and exhaust penetrations
  • Electrical conduits
  • Metal-roof repair work

Applicable Standards

  • AS 1530.8.1

FAQ

Red Dektite - No. 4 - Frequently Asked Questions

What pipe size does Dektite No. 4 fit?

Red Dektite - No. 4 covers pipe outside diameter from 75 to 160 mm, equivalent to 3 to 6 1/4 in. Measure the pipe outside diameter at the roofline. Do not select from the nominal bore or trade name because that measurement may be different.

What does the Dektite number mean?

The No. 4 is the manufacturer size code. It is not 4 mm or 4 inches. Use the pipe range shown beside each option in the size table.

Should I choose standard EPDM or red silicone?

Standard EPDM suits most cold and moderate-temperature roof penetrations and is rated from -50°C to 115°C continuously. Red silicone is intended for hotter flues and is rated from -50°C to 200°C continuously. Confirm the temperature at the roofline, not only the appliance outlet temperature.

How is a Dektite fitted to a metal roof?

Mark and cut the cone below the measured pipe diameter, slide it over the penetration, form the base to the roof profile, then seal and fasten it using the manufacturer spacing. A qualified roof plumber should complete the work where weatherproofing or fire separation is regulated.

Complete the order

Recommended for this job

Priced catalogue lines related to this product, including relevant fixings, sealants and materials. Every item shown here can be added to your cart.

View all products
Available

Bricon Industries

ALC01-50 AQUADAPT ALUMINIUM CLIP - 50/PACK
$35.24ex GST
Available

**ALL STEEL AND STUMP SUPPLIES PTY LTD

Precast Concrete Stump - 200 x 200 x 305mm
$77.50ex GST
Available

**ALL STEEL AND STUMP SUPPLIES PTY LTD

Precast Concrete Stump - 200 x 200 x 457mm
$116.25ex GST
Available

**ALL STEEL AND STUMP SUPPLIES PTY LTD

Precast Concrete Stump - 200 x 200 x 610mm
$154.97ex GST
Available

AMES AUSTRALASIA PTY LTD

Wrecking Bar - 460mm
$26.80ex GST
Available
Available
Available

Need Red Dektite - No. 4 for your job?

Order catalogue lines, request a custom-cut order, or send a trade account enquiry for repeat purchasing and account pricing.