Red Dektite - No. 1 is a flexible metal-roof penetration flashing for round pipes and flues measuring 5 to 60 mm. Select by actual outside diameter, not nominal pipe size.
- Dektite Option
- No. 1
- Roof Pitch
- 0° to 40°
- Pipe outside diameter
- 5 to 60 mm(1/4 to 2 1/2 in)
- Material
- High-temperature silicone, -50°C to 200°C continuous
- Category
- accessories
- Pipe outside diameter: 5 to 60 mm
- High-temperature silicone, -50°C to 200°C continuous
- Roof pitch range: 0° to 40°
- Flexible reinforced base forms to profiled metal roofing
- Marked cone guides trimming to the measured penetration
POA
Price on Application
This product is custom-cut, large-volume or project-specific. Submit a quote request and our trade desk will respond within 2 business hours.
Overview
Red Dektite - No. 1 seals round pipes and flues where they pass through profiled metal roofing. The flexible reinforced base forms to corrugated and ribbed roof sheets, while the cone is trimmed at the marked diameter to make close contact around the penetration.
The No. 1 mark is a product size code, not a pipe measurement. This option covers pipe outside diameter from 5 to 60 mm (1/4 to 2 1/2 in). Measure the outside of the installed pipe, including any insulation or outer casing that passes through the flashing, before choosing a size.
High-temperature silicone is rated for -50°C to 200°C continuous. This option is listed for roof pitches from 0° to 40°. Use the manufacturer installation method, approved sealant and suitable roof fasteners. Installation by a qualified roof plumber is recommended because poor trimming or fixing can cause water entry.
Choose the right Dektite size
The number is a product code, not the pipe diameter. Measure the outside diameter of the pipe, flue or post where it passes through the roof, then match that measurement to the range below.
01
Measure outside diameter
Measure the full outside width at the roofline. Include insulation or casing that must pass through the boot.
02
Match the stated range
Choose the smallest option whose range contains the measurement and whose base can form over the roof ribs.
03
Choose the material
Use standard EPDM for normal roof temperatures, red silicone for hot flues, and square for square posts.
| Option | Penetration Size | Material & Use | SKU | Price | Order |
|---|---|---|---|---|---|
| Standard No. 1Standard pipe | 5 to 60 mm1/4 to 2 1/2 in | EPDM rubber-50°C to 115°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1USA7QD | POA | Get quote |
| Standard No. 2Standard pipe | 45 to 80 mm1 3/4 to 3 1/4 in | EPDM rubber-50°C to 115°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1USA8H2 | POA | Get quote |
| Standard No. 3Standard pipe | 5 to 127 mm1/4 to 5 in | EPDM rubber-50°C to 115°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1USA97R | POA | Get quote |
| Standard No. 4Standard pipe | 75 to 160 mm3 to 6 1/4 in | EPDM rubber-50°C to 115°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1USA9YG | POA | Get quote |
| Standard No. 5Standard pipe | 108 to 190 mm4 1/4 to 7 1/2 in | EPDM rubber-50°C to 115°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1USAAP5 | POA | Get quote |
| Standard No. 6Standard pipe | 125 to 230 mm5 to 9 in | EPDM rubber-50°C to 115°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1USABFU | POA | Get quote |
| Standard No. 7Standard pipe | 150 to 280 mm6 to 11 in | EPDM rubber-50°C to 115°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1USAC6J | POA | Get quote |
| Standard No. 8Standard pipe | 175 to 330 mm7 to 13 in | EPDM rubber-50°C to 115°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1USACX8 | POA | Get quote |
| Red silicone No. 1Hot flue | 5 to 60 mm1/4 to 2 1/2 in | High-temperature silicone-50°C to 200°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1NA9ICN | POA | Get quote |
| Red silicone No. 2Hot flue | 45 to 80 mm1 3/4 to 3 1/4 in | High-temperature silicone-50°C to 200°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1NA9J3C | POA | Get quote |
| Red silicone No. 3Hot flue | 5 to 127 mm1/4 to 5 in | High-temperature silicone-50°C to 200°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1NA9JU1 | POA | Get quote |
| Red silicone No. 4Hot flue | 75 to 160 mm3 to 6 1/4 in | High-temperature silicone-50°C to 200°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1NA9KKQ | POA | Get quote |
| Red silicone No. 5Hot flue | 108 to 190 mm4 1/4 to 7 1/2 in | High-temperature silicone-50°C to 200°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1NA9LBF | POA | Get quote |
| Red silicone No. 6Hot flue | 125 to 230 mm5 to 9 in | High-temperature silicone-50°C to 200°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1NA9M24 | POA | Get quote |
| Red silicone No. 7Hot flue | 150 to 280 mm6 to 11 in | High-temperature silicone-50°C to 200°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1NA9MST | POA | Get quote |
| Red silicone No. 8Hot flue | 175 to 330 mm7 to 13 in | High-temperature silicone-50°C to 200°C continuousRoof pitch 0° to 40° | ACS-QUEENS-QSM-1NA9NJI | POA | Get quote |
| Square No. 3Square post | 20 to 125 mm3/4 to 5 in | EPDM rubber-50°C to 115°C continuousRoof pitch 0° to 45° | ACS-QUEENS-QSM-A1RMX3 | POA | Get quote |
Sizing reference: DEKS Dektite manufacturer chart. Confirm the measured penetration, roof pitch and service temperature before ordering.
Technical Specifications
| Dektite size | No. 1 |
|---|---|
| Pipe outside diameter | 5 to 60 mm |
| Imperial size range | 1/4 to 2 1/2 in |
| Material | High-temperature silicone |
| Continuous temperature range | -50°C to 200°C continuous |
| Roof pitch range | 0° to 40° |
| Selection measurement | Actual outside diameter, including any casing through the flashing |
| Unit of measure | each |
Compliance
Standards & Certifications
DEKS sizing reference
The displayed 5 to 60 mm range comes from the manufacturer chart for this Dektite size. Always check the actual outside diameter before ordering.
DEKS Dektite sizing chart
UV and fire test information
DEKS lists UV testing and AS 1530.8.1 certification for the Dektite range. Check the selected material and project fire requirements before specification.
AS 1530.8.1
Datasheets, Guides & Certificates
Manufacturer documentation for specification and compliance. Links open the original source documents.
Use Cases
- Plumbing vent pipes
- Hot and cold flues
- HVAC and exhaust penetrations
- Electrical conduits
- Metal-roof repair work
Applicable Standards
- AS 1530.8.1
FAQ
Red Dektite - No. 1 - Frequently Asked Questions
What pipe size does Dektite No. 1 fit?
Red Dektite - No. 1 covers pipe outside diameter from 5 to 60 mm, equivalent to 1/4 to 2 1/2 in. Measure the pipe outside diameter at the roofline. Do not select from the nominal bore or trade name because that measurement may be different.
What does the Dektite number mean?
The No. 1 is the manufacturer size code. It is not 1 mm or 1 inches. Use the pipe range shown beside each option in the size table.
Should I choose standard EPDM or red silicone?
Standard EPDM suits most cold and moderate-temperature roof penetrations and is rated from -50°C to 115°C continuously. Red silicone is intended for hotter flues and is rated from -50°C to 200°C continuously. Confirm the temperature at the roofline, not only the appliance outlet temperature.
How is a Dektite fitted to a metal roof?
Mark and cut the cone below the measured pipe diameter, slide it over the penetration, form the base to the roof profile, then seal and fasten it using the manufacturer spacing. A qualified roof plumber should complete the work where weatherproofing or fire separation is regulated.